Текст
CHECKLIST PS - 600 D [i LJ P This small book should be a help for the Service Departement. During installation and explication of the system, the user should be trained how to use it. When there is a breakdown on the system, the user himself should test the system as far he is able. Telling the Service Departement the fault and till what STEP he could do the test, would be a great deal to prepare the material for the intervention. At the end, the Service should be more efficient, and the user more satisfied. о о о GENERAL RELIARKS : I) Regard all conditions of installation, particulary power and ground. 2) Read the book before you use it RA 108 К A 108 1 *-* ME MORY M 1609 M ICROPRCb ad ress a d r e s s ---------- in hJ M ° и ьЗ NO PROGRAMME FIXE DISC. COMPLETE TEST OF SYSTEM NECESSARY OR ON По STEP 7 Yes 8 STEP К No STEP 9 No STEP 10 Yes No STEP 100 Yes STEP To ( B) Yes STEP STEP 10I 12 (C) 'J No STEP 13 Id I STEP 10? PRESS ANY KEY ON PERZPHERIAL display VI3U TOTAL FAULT OF KA 106 M 1662 M 1664 CHECK FUSES OF POWER SUPPIY AND POWER SUPPLY IT-SELF KEYBOARD LAMPS—2—512— \ FREE 1LLU? CHECK DISC PO'WER SUPPLY, PY/B A1,A2 SIGNAL-DOWN TO SPEED ON A2 £ CALL,PS 600 (RC) ERRORS ^PRINTOUT OF - N_ - PERIPH.DE SERVICER CHECK FUSE, CHECK ALL PLUGS INSIDE DISC, REFERE TO DISC MANUAL • CONNECT ГТ (Г1В) CONNECT IT (PED) DISC REA]jY - LAMP ILIUM.? TYPE ZJOB,1(RC) ERRORS NSvVER CORRECTLY TO YOUR CONFIGURATION ERRORS DISC CONNECTED PRINTOUT OF No CONNECTED TO POWER STEP 14 FUNCTION DOESN’T WORK es TTY DI A BIO HARMONIC function OTHER FUNCTIONS D.O.S Yes TO POWER Yes CHECK FUSES AND POWER SUPPLY OF EXT.CHASSIS CHECK ALSO TELECONMANDE IN MAINSUPPLY OF Ы 20 По STEP ЮЗ Ho 107 Yes STEP 104 STEP 105 No STEP 106 NO TTY Yes AT THE END OF LOADING TTY or DIABLO RINGS THE TAPE IS STOPPED AT THE END OF LOADING SYSTEM CONNECTED 0 TTY SYSTEM ONNECTED TO OPTICAL READER LOADING OF THE TAPE PUT SENSE SWITCHES 2 and 4 DOWN,STEP,CLOCK,RESET run, RUN - LAMP ILLUM. no ---REPAIR IT EXT. 11. ?0 CON- NECTED TO POWER COMO ND "WPR BETWE (E) CHECK ALL POWER SUPPLIES OF M 20 FOR + 5V.+I2V, -16,75V, O.K.? CONNECT IT (DEB) STEP (3) PLACE TAPE PSA/MET-3D ON OPTICAL READER PRESS RETURN ON TTY OR DIABLO. Was ... a response of M^O TTY 'ON - LINE CONNECTED TD PS. ? Mo Yes (R) yes IN MAIN-OWER SUPPLY IS 0 Volt ? no REPAIR IT yes No CALL FOR PIACE TAPE MA-TM-I5 ON OPTICAL READER PRESS- R - ON TTY or DIABLO. LOADING OF THE TAPE (9) I 6 /.1.x. SENSE SWITCH F: UP. STEP,CLOCK, RESET, RUN I STEP 108 ********* 0 }£ ********* 0 g 1 ( 11 ) о t4 TEST MEMOIRE M20 8 for 4 for 2 for 32 К 16 К 8 К C for 48 К NOMBRE DE FOIS 4 К G for 64 К MENOIRES M200/I/2 9 N * O.K. 0 0 6 0 0 0 2 0 BIT, WHICH IS NOT к 0 0 CORRECT CORRECT TAKE OFF THE DEFECT MEMORY AND CALL FOR REPLACEPdENT For DETAILED DESCRIPTIONS LOOK IN DI/S/M20/009 6000 is the adress in fault 20 is the contents which lias been read 00 is the contents which was expected LOAD PSA/MET-3D rN THE SAME MANNER AS BEFORE ALL SENSE SWITCHES UP.PLACE MA-T1-56 ON OPTICAL READER 12 TEST INSTR:VITON М2 0-5/6 0123456789ABCDEF * 1 HALT S1 . * 2 halt si; * 3 HALT-* RUN ж J El HALT-*INT S2,S3 S2’S3 S4^ RUN S4a RUN OK OK OK OK FOR DETAILED DESCRIPTIONS LOOK IN DI/S/H2O/OI3 STEP 109 >Л •' SAVE LAMP EXTING. DISC DRIVE NOTA- No Yes STEP III 90 Sec. DO USE A WITHOUT CARTRIDGE INFORMAT ION Yes Yes FOR OPTICAL REABER SV/ITCH OFF BISC DRIVE WAIT FOR SAVE LAMP, USE A DISC WITHOUT INFORMATION, CLEAN IT TEST BISQUE AB. DSK ? 6 ABM 1 ? 0 M1 601 ? N AB.ABM ? 16 AB. UNITE 1 NB BSK 2 b- 2 BOTH BISKS ARE 1 ONLY CARTRIDGE IS NB ТЕК ? Ло — 260 TESTS CHOISIS NUMBER OF TRACKS TESTEB YOU WILL TEST 1 - 405 f 2(30'2$o PLACE CN/AA/TEST-BSK-I670 °N REAPER ANB PRESS -R-ON TTY or DIABLO. LOADING OF THE TAPE PLACE CN/AA/TEST-DSK-I670 ON TTY READER AND PRESS-F- ON TTY. LOADING OF THE TAPE AT THE EBB OF LOADING, TAPE STOPS. STEP,CLOCK, RESET RUN. BEFORE STARTING THE BIALOG, DON’T FORGET TESTING OF BOTH BISKS DESTROYS YOUR PROGRAMMES ON FIX DISC. MOBELES ? ? S1 ON ? wo 0 TO 0 VO 0 TS N PO 0 so 0 TG 0 WP N 1er CYL NP 0004 wooo TOGO VOOO POOO SOPP SKOO ТЕ TW TL TP TF TC TI 00000000 00000000 00000000 00000000 00000000 00000000 00000000 I ; A CORRECT PRINT-OUT dr t, /.t-di.v. BID YOU OBTAIN IT ? t Yes No DETAILED INFORMATION IN J.74.4O9 STEP 113 STEP II:.’ 9 FAULT ON PROCESSOR OR microprogramme 10 STEP 114 □ rj [J rj rj rj J □ □ и у у у у rj STEP 115 PLACE MA-T1-56. ON TTY READER, PRESS RUN, TAPE LOADS 1 AT THE END OF LOADING M2O GOES TO HALT. TAPE STOPS LOADING I PUT LOADER MA-OOO-CEL-I5 ON TTY READER (2nd part, first RUB OUT ON READER) ST,S4 DOWN, STEP, CLOCK, RESET RUN, RUN ILLUM. START READER I lJ rj rj rj TAPE LOADS, END OF LOADER TAPE STOPS, Ы20 GOES TO HALT. PUT PSA-MET-3D ON TTY READER (after LOADER OF MET-3D) PRESS RUN ON M20 MET -3D IS LOADED. □ LI □ u rj rj R v> STEP 200 1 st TRY J [J rj fj rj 16 1-3 14 INTEtiCliAIIGE MEMORY 0-otiie 1.120 -3F THE SWITCH ON M20 STEP 202 STEP 203 R1 STEP 204 P-. 18 1 SWITCH OFF M20 RECONNECT ALL CARDS FROM M20, EXCEPT TTY INTERFACE, PROCESSOR W20, MICROPROGRAMME M 1360 ( MZ 60A 05) and 32 К MEMORY and M 1612 (OPTICAL READER SWITCH ON M 20 ONE OF THE REMAINING CARDS OR OPTICAL READER ITSELF HAS A BREAKDOWN. Ist TRY ГО 3 t-3 17 STEP 206 STEP 117 STEP 205 F J SWITCH OFF DISK-DRIVE WAIT TILL SAVE LAMP IS ILIUM. STEP 118 STEP I19 МАКЕ А COitfPLETE TEST LIKE IN (E) TM TI A 1 * DISC (all 4 surfaces). IF ALL IT SSEMS, PROGRAMME LOST ON FIX DISC, GO TO (E). AFTER (E), RETURN TO (S) E TEST OF SYSTEME S COPY PROGRAMME TO SENSE SWITCHES 3.4.DOWN STEP,CLOCK, RESET; RUN ПТ DP LV TTY PRINTS "PERIPH DE SERVICE Yes PRESS ANY KEY ON TTY PRINTOUT OF "RECOPIE EN COURS"- COPY STARK Yes X CORRECT x CARTRIDGE ON DISC. AT THE END OF THE COPY TTY SHOULD PRINT : "RECOPIE terminee.changer DE DISQUE AMOVIBLE" STEP 123 TEST X DISC WAS DE ON BOTH AND ON TRACKS Yes DISC’S 400 SWITCH OFF DISC-DRIVE, WAIT TILL SAVE IS ILLUM CHANGE CARTRIDGE, DISC-DRIVE-ON DEB STEP 124 _________________i 1) CARTRIDGE ITSELF DEFECT. 2) CARTRIDGE HOT COMPATIBLE WITH HEADS DO STEPS 207 TO 219 ONLY IF YOU HAVE GOOD KNOWLEDGE OF PS. STEP 211 STEP 212 STEP 213 STEP 214 23 '•1 t 23 SAVE - OK. SWITCH ON DISK DRIVE STEP 215 READY Mo again LET IT RUN NOW 30 min 214 STEP 216 RADIAL TEST FuR HEAD О ON TTY : Q 1OOO D2 P146 S24 N.I ( RC) TTY PRINTS ERROR MESSAGE CHECK WITH SCOPE SYNCHRO ON TP 12 ON Al BOARD CHECK TP3 ON A4 BOARD DETAILED INFORMATION IN DISK MANUAL. STEP 217 RADIAL TEST FOR HEAD 1 ON TTY: Q 1000 D2 P146 SO N1 ( RC) THE SAME AS FOR HEAD 0 STEP 218 CIRCUMFERENTIAL TEST ON TTY q’ 1000 D2 РЮ SO N1 ( RC) SYNCHRO ON cli 1 TP 12 on Al - NEGATIVE CHECK on ch. 2 TP3 on A4 DETAILED INFORMATION IN DISK MANUAL J STEP 219 SWITCH OFF DISC DRIVE, WAIT TILL SAVE -SWITCH OFF COMPLETTY, MAKE STRAP -H- on Al LACK ON ITS OLD POSITION (TO JC) TAKE OFF CE"CARTRIDGE S STEP 126 STEP 127 ТЕР 128 STEP STEP 129 130 г 24 CHECK Z OUT PUT OF KA 106 WITH SCOPE. IF NO SIGNAL-------------- LOOK ON KA 106 BOARD - ANA N. LISTEN, THT IS WORKING. YOU COULD HEAR IT ? No CHECH + 200 V IN KA 106 CHECK RELAIS IN CRT MODULE. CHECK FUSE I.6A IN CRT MODULE STEP DO STEP 220 TO 223 ONLY IF YOU GOOD KNOW-LEDGE OF PS. f HAVE STEP 220 SWITCH OFF SYSTEM COMPLETLY DISCONNECT 2 AND M 1664 - DISCONNECT 2 AND MI662. CABLES BETWEEN KA 106 CABLES BETWEEN M.I664 CONNECT THE 2 CABLES OF KA 106 DIRECTLY TO MI662 25 ~ STR! CALL YOUR PROGRAMME FAULT ON Ы 1662 or KA TO6 FAULT ON M 1664 SWITCHING FROM SPECTRE CARACTER SPECTRE MAY BE WRONG STEP 223 SWITCH OFF POWER CONNECT SYSTEM AS IT WAS BEFORE STEP 220 STEP 132 ___________i____________ WHAT FAULT ON DISPLAY ? STEP I33 M 26 CHECH CLOCK OUTPUT OF HT 135 : NO ADVANCE ADRESS TO Ы1663-1 or Ы 1663-1 HAS A BREAKDOWN PRESS I NT on M20 TO GET BACK TO MONITOR OF PS STEP 136 + 5V 15 V 9 1) CHECK INSIDE YT 135 : + 5 V CORRECT ? 2) CHECK INSIDE CT 135: + I5V -CORRECT O.K. TAKE SIGNAL OF GENERATOR AND PUT IT DIRECTLY TO CTI35 INPUT P.H.A. TRY IT FROM (26) AGAIN I_____________________ MAKE A PRINTOUT OF SOME CHANNEL OF BLOC О IN ORDER TO CHECK CARACTERISTIC OF DATA BETWEEN + 2000 STEP 137 1) FAULT ON M 1604 2) CABLE BETWEEN M 1604 AND HT 135 3) HT 135 NUMBER OF CHANNELS NOT CORRECT O.K. к STEP В8 IF YOU HAVE SOME PROBLEMS WITH DISC, YOU SHOULD PERFORM TEST DISC ON BOTH DISKS FOR 400 TRACKS. 2nd TRY TEST DISK AND DISPLAY DESCRI- BED IN 1.74.409 SAVE YOUR INFOBMAT ION OF FIX DISK. USE A CARTRIDGE WITHOUT DATA INSPECT ALL 4 HEADS AND CLEAN DISKS. ** GO TO SECTION (E) INPUT (U) STEP 139 STEP 140 L 27 27 i _________________ PLACE TAPE MA-TBMX - 15 ON HEADER (R)FOR OPTICAL, F) FOR TTY) LOADING OF TEST FOR MAGN. TAPE MAKE STEP, CLOCK, RESET, RUN FOR DETAILED INFORMATION, LOOK IN GA/M2O/O48 TEST COUPLEUR BANDE Ml653 ADR.COUPLEUR BANDE ? 7 (Jfp ADM M.1662 NUMERO DU DEROULEUR SELECTE ? 0 I»****»»»»»»*»»** # 00 ТЕ 00000000 «и*»»*»»**»» O.K THIS IS A CORRECT PRINTOUT OF TEST MAGN.TAPE N STE1 142 SWITCH ON KA 108 PUT IT ON LOCAL AFTER 30 sec. PRESS PAGE s i POSSI- BLE TO SWITCH ON CHECK FUSES AND POWER POWER SUPPLY OF KA108 No STEP 143 No SWITCH TO LINE CHECK IT ON LOCAL REFERING TO TEKTRONIX MANUAL O.K FAULT ON KAI08 STEP 144 No STEP 145 CHECK IT ON LINE O.K. M 1609 IN M20 EXT. OR DATA COMMUNICATION INTERFACE IN KA 108 DEFECT. LOOK IN CORRESPONDING MANUAL FOR REPAIR 28 SWITCH TO LINE | CALL PROGRAMME MET FROM DISC PLACE ГЯА-ТТ1-56 ON OPTICAL READER STEP 146 TAPE LOADES END OF LOADING TAPE STOPS MAKE3PEP, CLOCK, RESET, RUN. STEP 147 DETAILED INFORMATION IS GIVEN IN DI/S/M2O/O11 TEST CORRESPONDES ONLY 100$ FOR TTY FOR DIABLO : KEYBOARD, PUNCHER - TEST DOESN’T CORRESPOND. READER AND IF -R- DOESN'T WORK PROCEED AS FOLLOW STEP 148 PLACE LOADER MA 100 CEL 15 ON OPTICAL READER SENSE SWITCH 2,4 DOWN. STEP, CLOCK, RESET, RUN LOADER IS CHARGED. PLACE MA-TT1-56 ON OPTICAL READER, PRESS RUN. TAPE IS LOADED. STEP 149 CONFIGURATION MICROPROGRAM. STEP 150 CONFIGURATION SFT 135 ? STEP 151 MAKE TEST MEMORY. MAKE TEST INSTRUCTION GO TO (3) AND PROCEES TILL STEP 109 IF NO FAULT ON TESTS, Ш58А6О -( MI358) MICROPROGRAMME HAS A BREAKDOWN; VERY FEW CHANCES THAT PROCESSOR M20 HAS A BREAKDOWN. (SAVE L OR SECOND GROUP OF FILE REGISTERS) STEP 152 STEP 153 SERIOUS BREAKDOWN EITHER ON MI662 Je3 or SFT 135 29 STEP 154 HAS SP^C’j RA NOISE AFTER Yes FAULT COULD BE ON ARITHETICE BOARD IN SFT 135 OR ITS CABLES CALL FOR SERVICE AND TELL THE BREAKDOWN Q STEP 155 I IF YOU HAVE A PROGRAMMED FUNCTION OUT OF SERVICE, PROCEED AS FOLLOW : 1) Test MEMORY 2) TEST INSTRUCTION 3) TEST DISC ( SAVE DATA BEFORE FROM FIX DISC.) 4) COPY SEDIM-C ON FIX DISC TRY IT AGAIN